Regular arc-shaped scratches at the edge; replacing the brush roller only provides short-term improvement
- Background
- In the post-CMP cleaning section, regular arc-shaped scratches appeared within a 5 mm annular band at the wafer edge. Replacing the brush roller improved the condition temporarily, but the scratches reappeared within two weeks.
- Evaluation
- Disassembly revealed a sudden change in hardness at the brush roller end and mold flash on the end face; at the same time, shaft-end runout exceeded the recommended limit for that rotational speed. Contact pressure was concentrated at the end, forming a fixed arc.
- Action
- A transition treatment was applied to the end, with end-face flatness and runout controlled as separate items; compression was mandatorily retested after roller replacement.
- Results
- The scratches did not recur, and particle counts remained at the baseline.